System Administration > Configuration > Fabric > Nodes > Transport Nodes

Set VDS configuration and create it in vCenter (Deprecated)

Upon successful preheck status goes to PENDING_TOPOLOGY and global
recommended topology is generated which can be retrieved via
GetRecommendedVdsTopology API. User can apply the entire recommeneded
topology all together or can apply partial depending on which
TrasportNodes user wants to be upgraded from NVDS to CVDS.
User can change system generated vds_name field, all other fields cannot
be changed when applying topology.

Request:

Method:
POST
URI Path(s):
/api/v1/nvds-urt/topology?action=apply
Request Headers:
n/a
Query Parameters:
SetTargetVdsTopologyParameters+
Request Body:
UpgradeTopology+

Example Request:

PUT https://<nsx-mgr>/api/v1/nvds-urt/topology?action=apply { "topology": [ { "nvds_id": "bb 23 24 9d e4 0a 4c 62-91 9b 77 66 55 29 4c 92", "nvds_name": "mynvds1", "compute_manager_topology": [ { "compute_manager_id": "ddb8efeb-581e-435a-93b7-f95da399d7e0", "dvswitch": [ { "data_center_id": "domain-c8:70dade9c-eaf2-462b-9005-7ecf14595c19", "vds_name": "myvds1", "transport_node_id": ["674007b3-5671-4409-911f-1c191ef492f7"] } ] } ] } ] }

Successful Response:

Response Code:
200 OK
Response Headers:
Content-type: application/json
Response Body:
UpgradeTopology+

Example Response:

{ "topology": [ { "nvds_id": "bb 23 24 9d e4 0a 4c 62-91 9b 77 66 55 29 4c 92", "nvds_name": "mynvds1", "compute_manager_topology": [ { "compute_manager_id": "ddb8efeb-581e-435a-93b7-f95da399d7e0", "dvswitch": [ { "data_center_id": "domain-c8:70dade9c-eaf2-462b-9005-7ecf14595c19", "vds_name": "myvds1", "transport_node_id": [ "674007b3-5671-4409-911f-1c191ef492f7" ] } ] } ] } ] }

Required Permissions:

crud

Feature:

nodes_transport_nodes

Additional Errors: