Data Object - VsanNetworkConfigPnicSpeedInconsistencyIssue(vim.vsan.VsanNetworkConfigPnicSpeedInconsistencyIssue)

Extends
VsanNetworkConfigBaseIssue
See also
DistributedVirtualSwitch, HostSystem
Since
vSAN API 6.6

Data Object Description

Configuration issue: vSAN is using a vmknic on a vSwitch which has inconsistent physical NIC speeds. It is recommended to only use physical NICs of same speed on a given vSwitch backing vSAN. Note that physical NIC redundancy is a best practice, not a functional/support requirement.

Properties

Name Type Description
hostManagedObjectReference
to a HostSystem

The Host on which the vmknic exists
speedsMbxsd:long[]

Bit rates (speed) of the links, in Mbit/s. This list only contains each present speed once. Links without any speed indication (e.g. links that are down) are not considered in the list. As there is an issue, there must be at least two members in this list.
vds*ManagedObjectReference
to a DistributedVirtualSwitch

The Virtual Distributed Switch, if in-use.
vswitchName*xsd:string

Standard virtual switch name, in case of VMware Standard Switch (VSS).
Properties inherited from VsanNetworkConfigBaseIssue
None
Properties inherited from DynamicData
None
*Need not be set
Show WSDL type definition