Data Object - VsanNetworkConfigVswitchWithNoRedundancyIssue(vim.vsan.VsanNetworkConfigVswitchWithNoRedundancyIssue)

Extends
VsanNetworkConfigBaseIssue
See also
DistributedVirtualSwitch, HostSystem
Since
vSAN API 6.6

Data Object Description

Configuration issue: vSAN is using a vmknic on a vSwitch which doesn't have any physical NIC redundancy. This means in case of a physical NIC failure vSAN would not be able to use the vmknic any more to communicate with the remaining cluster. Note that physical NIC redundancy is a best practice, not a functional/support requirement.

Properties

Name Type Description
hostManagedObjectReference
to a HostSystem

The Host on which the vmknic exists
numPnicsxsd:long

Number of configured physical NICs.
vds*ManagedObjectReference
to a DistributedVirtualSwitch

The Virtual Distributed Switch, if in-use.
vswitchName*xsd:string

Standard virtual switch name, in case of VMware Standard Switch (VSS).
Properties inherited from VsanNetworkConfigBaseIssue
None
Properties inherited from DynamicData
None
*Need not be set
Show WSDL type definition