System Administration > Configuration > Fabric > Nodes > Transport Nodes

Get a Host Transport Node's State

Returns information about the current state of the transport node
configuration and information about the associated hostswitch.
Change introduced in 4.1.2 for ESX Transport node - The vib details will
not be retrieved in every state API call. It will be retrieved by periodical
polling on the host. Therefore the nsx vib version mismatch or nsx vib absence
will be reported by this API only after subsequent polling takes place.
Currently, the poll frequency is 10 minutes.
This API is available when using VMware Cloud (AWS, Dell-EMC, Outpost, Hyperscalers) or VMware NSX.

Request:

Method:
GET
URI Path(s):
/policy/api/v1/infra/sites/{site-id}/enforcement-points/{enforcementpoint-id}/host-transport-nodes/{host-transport-node-id}/state
Request Headers:
n/a
Query Parameters:
n/a
Request Body:
n/a

Example Request:

GET https://<nsx-mgr>/policy/api/v1/infra/sites/<site-id>/enforcement-points/<enforcementpoint-id>/host-transport-nodes/55120a1a-51c6-4c20-b4a3-6f59662c9f6a/state example_response: | { "transport_node_id": "55120a1a-51c6-4c20-b4a3-6f59662c9f6a", "host_switch_states": [ { "host_switch_id": "50 21 0c 52 94 22 aa 20-b7 f0 0b da 1c 7c 29 ea", "host_switch_name": "dvs1", "endpoints": [ { "device_name": "vmk10", "ip": "172.16.223.175", "default_gateway": "", "subnet_mask": "255.255.224.0", "label": 53249 } ], "transport_zone_ids": [ "1b3a2f36-bfd1-443e-a0f6-4de01abc963e" ], "host_switch_type": "VDS" } ], "maintenance_mode_state": "DISABLED", "node_deployment_state": { "state": "success", "details": [] }, "deployment_progress_state": { "progress": 100, "current_step_title": "Configuration complete" }, "state": "success", "details": [ { "sub_system_id": "55120a1a-51c6-4c20-b4a3-6f59662c9f6a", "sub_system_type": "HostConfig", "state": "success" }, { "sub_system_id": "55120a1a-51c6-4c20-b4a3-6f59662c9f6a", "sub_system_type": "AppInit", "state": "success" }, { "sub_system_id": "55120a1a-51c6-4c20-b4a3-6f59662c9f6a", "sub_system_type": "LogicalSwitchFullSync", "state": "success" } ] }

Successful Response:

Response Code:
200 OK
Response Headers:
Content-type: application/json
Response Body:
TransportNodeState+

Required Permissions:

read

Feature:

nodes_transport_nodes

Additional Errors: