Enum - VsanEncryptionIssue(vim.host.VsanEncryptionIssue)

Since
vSAN API 6.6


Enum Description

The vSAN encryption issue enumeration.

Enum Constants

NameDescription
clientcertificateinconsistent The client certification on the host is inconsistent with the cluster encryption configuration.
clientkeyinconsistent The client private key on the host is inconsistent with the cluster encryption configuration.
cmkcannotretrieve

Since vSAN API vSAN 6.7U1
cmknotinenabledstate

Since vSAN API vSAN 6.7U1
dataencryptionkeyinconsistent The Data Encryption Key generation number on the host/disk is inconsistent with the cluster encryption configuration but may be consistent with the cluster old Data Encryption Key.
dataencryptionkeyverifierinconsistent

Since vSAN API 7.4
dataencryptionkeyverifierofdiskmetainconsistent

Since vSAN API 8.0.0.3
disabledwhenclusterenabled Encryption is disabled on the host/disk when the cluster has encryption enabled.
diskhaspendingdeeprekey

Since vSAN API 8.0.0.3
diskhaswrongdekid

Since vSAN API 8.0.0.3
diskhaswrongpendingdekid

Since vSAN API 8.0.0.3
enabledwhenclusterdisabled Encryption is enabled on the host/disk when the cluster has encryption disabled.
erasedisksbeforeuseinconsistent The configuration of erasing disks before use on the host is inconsistent with the cluster encryption configuration.
hostencryptiondekidinconsistent

Since vSAN API 8.0.0.1
hosthaspendingdeeprekey

Since vSAN API 8.0.0.3
hosthaswrongdekid

Since vSAN API 8.0.0.3
hosthaswrongolddekid

Since vSAN API 8.0.0.3
hostkeyinconsistent The host key for host core dump encryption is inconsistent with the cluster encryption configuration.
hostkeynotavailable

Since vSAN API 7.0
keknotavailable

Since vSAN API 7.0
keyencryptionkeyinconsistent The Encryption Key on the host/disk is inconsistent with the cluster encryption configuration.
keyencryptionkeyverifierinconsistent

Since vSAN API 7.4
kmsinfoinconsistent The Key Management Servers information on the host/disk is inconsistent with the cluster encryption configuration.
objectencryptioninconsistent

Since vSAN API 8.0.0.1
olddataencryptionkeyinconsistent

Since vSAN API 8.0.0.3
servercertificatesinconsistent The server certifications on the host is inconsistent with the cluster encryption configuration.
VsanEncryptionIssue_Unknown

Since vSAN API vSAN 6.7U3

Show WSDL type definition