Class CIM_AggregatePSExtentBasedOnAggregatePExtent


  extends CIM_BasedOn (Association)
This association is deprecated in lieu of ProtectedSpaceBasedOn, since AggregatePExtents and AggregatePSExtents are themselves deprecated. The association describes that AggregatePSExtents are BasedOn a single AggregatePExtent.
Details...
This class is not implemented.

Class Qualifiers

NameData TypeValueScopeFlavors
AssociationbooleantrueNone OVERRIDABLE= false
DeprecatedstringCIM_ProtectedExtentBasedOnTOSUBCLASS= falseNone
DescriptionstringThis association is deprecated in lieu of ProtectedSpaceBasedOn, since AggregatePExtents and AggregatePSExtents are themselves deprecated. The association describes that AggregatePSExtents are BasedOn a single AggregatePExtent.None TRANSLATABLE= true
UMLPackagePathstringCIM::Device::SccExtentsNone None
Versionstring2.8.0TOSUBCLASS= falseTRANSLATABLE= true

Local Class Properties

NameData TypeQualifiers
NameData TypeValueScopeFlavors
EndingAddressuint64
DescriptionstringEndingAddress indicates where in lower level storage, the higher level Extent ends. This property is useful when mapping non-contiguous Extents into a higher level grouping.None TRANSLATABLE= true
OrderIndexuint16
DescriptionstringIf there is an order to the BasedOn associations that describe how a higher level StorageExtent is assembled, the OrderIndex property indicates this. When an order exists, the instances of BasedOn with the same Dependent value (i.e., the same higher level Extent) should place unique values in the OrderIndex property. The lowest value implies the first member of the collection of lower level Extents, and increasing values imply successive members of the collection. If there is no ordered relationship, a value of zero should be specified. An example of the use of this property is to define a RAID-0 striped array of 3 disks. The resultant RAID array is a StorageExtent that is dependent on (BasedOn) the StorageExtents that describe each of the 3 disks. The OrderIndex of each BasedOn association from the disk Extents to the RAID array could be specified as 1, 2 and 3 to indicate the order in which the disk Extents are used to access the RAID data.None TRANSLATABLE= true
StartingAddressuint64
DescriptionstringStartingAddress indicates where in lower level storage, the higher level Extent begins.None TRANSLATABLE= true

Association References

NameClass OriginReference Class
AntecedentCIM_AggregatePSExtentBasedOnAggregatePExtentCIM_AggregatePExtent
DependentCIM_AggregatePSExtentBasedOnAggregatePExtentCIM_AggregatePSExtent

Copyright © 2008-2010 VMware, Inc. All rights reserved.