Class CIM_AlertIndication


  extends CIM_ProcessIndication
A concrete superclass for CIM Alert notifications. An AlertIndication is a specialized type of CIM_Indication that contains information about the severity, cause, recommended actions and other data of a real world event. This event and its data may or may not be modeled in the CIM class hierarchy.
Details...
This class is not implemented.

Subclasses

 CIM_AlertInstIndication  CIM_IndicationSubscriptionAlert  CIM_SecurityIndication  CIM_ThresholdIndication  OMC_IpmiAlertIndication  VMware_AlertIndication

Class Qualifiers

NameData TypeValueScopeFlavors
DescriptionstringA concrete superclass for CIM Alert notifications. An AlertIndication is a specialized type of CIM_Indication that contains information about the severity, cause, recommended actions and other data of a real world event. This event and its data may or may not be modeled in the CIM class hierarchy.None TRANSLATABLE= true
IndicationbooleantrueNone OVERRIDABLE= false
UMLPackagePathstringCIM::EventNone None
Versionstring2.8.1000TOSUBCLASS= falseTRANSLATABLE= true

Local Class Properties

NameData TypeQualifiers
NameData TypeValueScopeFlavors
AlertingElementFormatuint16
DescriptionstringThe format of the AlertingManagedElement property is interpretable based upon the value of this property. Values are defined as: 0 - Unknown. The format is unknown or not meaningfully interpretable by a CIM client application. 1 - Other. The format is defined by the value of the OtherAlertingElementFormat property. 2 - CIMObjectPath. The format is a CIMObjectPath, with format <NamespacePath>:<ClassName>.<Prop1>="<Value1>", <Prop2>="<Value2>", . . . specifying an instance in the CIM Schema.None TRANSLATABLE= true
ModelCorrespondencestringCIM_AlertIndication.AlertingManagedElement, CIM_AlertIndication.OtherAlertingElementFormatNone None
ValueMapstring0, 1, 2None None
ValuesstringUnknown, Other, CIMObjectPathNone TRANSLATABLE= true
AlertingManagedElementstring
DescriptionstringThe identifying information of the entity (ie, the instance) for which this Indication is generated. The property contains the path of an instance, encoded as a string parameter - if the instance is modeled in the CIM Schema. If not a CIM instance, the property contains some identifying string that names the entity for which the Alert is generated. The path or identifying string is formatted per the AlertingElementFormat property.None TRANSLATABLE= true
ModelCorrespondencestringCIM_AlertIndication.AlertingElementFormatNone None
AlertTypeuint16
DescriptionstringPrimary classification of the Indication. The following values are defined: 1 - Other. The Indication's OtherAlertType property conveys its classification. Use of "Other" in an enumeration is a standard CIM convention. It means that the current Indication does not fit into the categories described by this enumeration. 2 - Communications Alert. An Indication of this type is principally associated with the procedures and/or processes required to convey information from one point to another. 3 - Quality of Service Alert. An Indication of this type is principally associated with a degradation or errors in the performance or function of an entity. 4 - Processing Error. An Indication of this type is principally associated with a software or processing fault. 5 - Device Alert. An Indication of this type is principally associated with an equipment or hardware fault. 6 - Environmental Alert. An Indication of this type is principally associated with a condition relating to an enclosure in which the hardware resides, or other environmental considerations. 7 - Model Change. The Indication addresses changes in the Information Model. For example, it may embed a Lifecycle Indication to convey the specific model change being alerted. 8 - Security Alert. An Indication of this type is associated with security violations, detection of viruses, and similar issues.None TRANSLATABLE= true
MappingStringsstringRecommendation.ITU|X733.Event typeNone None
RequiredbooleantrueNone OVERRIDABLE= false
ValueMapstring1, 2, 3, 4, 5, 6, 7, 8None None
ValuesstringOther, Communications Alert, Quality of Service Alert, Processing Error, Device Alert, Environmental Alert, Model Change, Security AlertNone TRANSLATABLE= true
CorrelatedIndicationsstring
DescriptionstringA list of IndicationIdentifiers whose notifications are correlated with (related to) this one.None TRANSLATABLE= true
MappingStringsstringRecommendation.ITU|X733.Correlated notificationsNone None
ModelCorrespondencestringCIM_Indication.IndicationIdentifierNone None
Descriptionstring
DescriptionstringA short description of the Indication.None TRANSLATABLE= true
MappingStringsstringRecommendation.ITU|X733.Additional textNone None
EventIDstring
DescriptionstringAn instrumentation or provider specific value that describes the underlying "real-world" event represented by the Indication. Two Indications with the same, non NULL EventID value are considered, by the creating entity, to represent the same event. The comparison of two EventID values is only defined for Alert Indications with identical, non NULL values of SystemCreateClassName, SystemName and ProviderName.None TRANSLATABLE= true
ModelCorrespondencestringCIM_AlertIndication.ProbableCauseNone None
EventTimedatetime
DescriptionstringThe time and date the underlying event was first detected. If specified, this property MUST be set to NULL if the creating entity is not capable of providing this information. This value is based on the notion of local date and time of the Managed System Element generating the Indication.None TRANSLATABLE= true
ModelCorrespondencestringCIM_AlertIndication.ProbableCauseNone None
IndicationFilterNamestring
DescriptionstringAn identifier for the indication filter that selects this indication and causes it to be sent. This property is to be filled out by the indication sending service. The value shall be correlatable with the Name property of the instance of CIM_IndicationFilter describing the criteria of the indication. The value of the IndicationFilterName should be formatted using the following algorithm: < OrgID > : < LocalID >, where < OrgID > and < LocalID > are separated by a colon (:) and < OrgID > shall include a copyrighted, trademarked, or otherwise unique name that is owned by the business entity that is creating or defining the value or that is a registered ID assigned to the business entity by a recognized global authority. In addition, to ensure uniqueness, < OrgID > shall not contain a colon (:).When using this algorithm, the first colon to appear in the value shall appear between < OrgID > and < LocalID >. < LocalID > is chosen by the business entity and shall be used uniquely.None TRANSLATABLE= true
ExperimentalbooleantrueTOSUBCLASS= falseNone
ModelCorrespondencestringCIM_IndicationFilter.NameNone None
IndicationIdentifierstring
DescriptionstringAn identifier for the Indication. This property is similar to a key value in that it can be used for identification, when correlating Indications (see the CorrelatedIndications array). Its value SHOULD be unique as long as correlations are reported, but MAY be reused or left NULL if no future Indications will reference it in their CorrelatedIndications array.To ensure uniqueness, the value of IndicationIdentifier should be constructed using the following "preferred" algorithm: <OrgID>:<LocalID> Where <OrgID> and <LocalID> are separated by a colon (:), and where <OrgID> must include a copyrighted, trademarked, or otherwise unique name that is owned by the business entity that is creating or defining the IndicationIdentifier or that is a recognized ID that is assigned to the business entity by a recognized global authority. (This requirement is similar to the <Schema Name>_<Class Name> structure of Schema class names.) In addition, to ensure uniqueness <OrgID> must not contain a colon (:). When using this algorithm, the first colon to appear in IndicationIdentifier must appear between <OrgID> and <LocalID>. <LocalID> is chosen by the business entity and should not be re-used to identify different underlying (real-world) elements. If the above "preferred" algorithm is not used, the defining entity should assure that the resulting IndicationIdentifier is not re-used across any IndicationIdentifiers that are produced by this or other providers for the NameSpace of this instance. For DMTF-defined instances, the "preferred" algorithm should be used with the <OrgID> set to CIM.None TRANSLATABLE= true
MappingStringsstringRecommendation.ITU|X733.Notification identifierNone None
IndicationTimedatetime
DescriptionstringThe time and date of creation of the Indication. The property may be set to NULL if the entity creating the Indication is not capable of determining this information. Note that IndicationTime may be the same for two Indications that are generated in rapid succession.None TRANSLATABLE= true
Messagestring
DescriptionstringThe formatted message. This message is constructed by combining some or all of the dynamic elements specified in the MessageArguments property with the static elements uniquely identified by the MessageID in a message registry or other catalog associated with the OwningEntity.None TRANSLATABLE= true
ExperimentalbooleantrueTOSUBCLASS= falseNone
ModelCorrespondencestringCIM_AlertIndication.MessageID, CIM_AlertIndication.MessageArgumentsNone None
MessageArgumentsstring
DescriptionstringAn array containing the dynamic content of the message.None TRANSLATABLE= true
ExperimentalbooleantrueTOSUBCLASS= falseNone
ModelCorrespondencestringCIM_AlertIndication.Message, CIM_AlertIndication.MessageIDNone None
MessageIDstring
DescriptionstringA string that uniquely identifies, within the scope of the OwningEntity, the format of the Message.None TRANSLATABLE= true
ExperimentalbooleantrueTOSUBCLASS= falseNone
ModelCorrespondencestringCIM_AlertIndication.Message, CIM_AlertIndication.MessageArgumentsNone None
OtherAlertingElementFormatstring
DescriptionstringA string defining "Other" values for AlertingElementFormat. This value MUST be set to a non NULL value when AlertingElementFormat is set to a value of 1 ("Other"). For all other values of AlertingElementFormat, the value of this string must be set to NULL.None TRANSLATABLE= true
ModelCorrespondencestringCIM_AlertIndication.AlertingElementFormatNone None
OtherAlertTypestring
DescriptionstringA string describing the Alert type - used when the AlertType property is set to 1, "Other State Change".None TRANSLATABLE= true
ModelCorrespondencestringCIM_AlertIndication.AlertTypeNone None
OtherSeveritystring
DescriptionstringHolds the value of the user defined severity value when 'PerceivedSeverity' is 1 ("Other").None TRANSLATABLE= true
ModelCorrespondencestringCIM_AlertIndication.PerceivedSeverityNone None
OwningEntitystring
DescriptionstringA string that uniquely identifies the entity that owns the definition of the format of the Message described in this instance. OwningEntity MUST include a copyrighted, trademarked or otherwise unique name that is owned by the business entity or standards body defining the format.None TRANSLATABLE= true
ExperimentalbooleantrueTOSUBCLASS= falseNone
PerceivedSeverityuint16
DescriptionstringAn enumerated value that describes the severity of the Alert Indication from the notifier's point of view: 1 - Other, by CIM convention, is used to indicate that the Severity's value can be found in the OtherSeverity property. 3 - Degraded/Warning should be used when its appropriate to let the user decide if action is needed. 4 - Minor should be used to indicate action is needed, but the situation is not serious at this time. 5 - Major should be used to indicate action is needed NOW. 6 - Critical should be used to indicate action is needed NOW and the scope is broad (perhaps an imminent outage to a critical resource will result). 7 - Fatal/NonRecoverable should be used to indicate an error occurred, but it's too late to take remedial action. 2 and 0 - Information and Unknown (respectively) follow common usage. Literally, the AlertIndication is purely informational or its severity is simply unknown.None TRANSLATABLE= true
MappingStringsstringRecommendation.ITU|X733.Perceived severityNone None
OverridestringPerceivedSeverityTOSUBCLASS= falseNone
RequiredbooleantrueNone OVERRIDABLE= false
ValueMapstring0, 1, 2, 3, 4, 5, 6, 7None None
ValuesstringUnknown, Other, Information, Degraded/Warning, Minor, Major, Critical, Fatal/NonRecoverableNone TRANSLATABLE= true
ProbableCauseuint16
DescriptionstringAn enumerated value that describes the probable cause of the situation which resulted in the AlertIndication.None TRANSLATABLE= true
MappingStringsstringRecommendation.ITU|X733.Probable cause, Recommendation.ITU|M3100.probableCause, ITU-IANA-ALARM-TCNone None
ModelCorrespondencestringCIM_AlertIndication.ProbableCauseDescription, CIM_AlertIndication.EventID, CIM_AlertIndication.EventTimeNone None
RequiredbooleantrueNone OVERRIDABLE= false
ValueMapstring0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48, 49, 50, 51, 52, 53, 54, 55, 56, 57, 58, 59, 60, 61, 62, 63, 64, 65, 66, 67, 68, 69, 70, 71, 72, 73, 74, 75, 76, 77, 78, 79, 80, 81, 82, 83, 84, 85, 86, 87, 88, 89, 90, 91, 92, 93, 94, 95, 96, 97, 98, 99, 100, 101, 102, 103, 104, 105, 106, 107, 108, 109, 110, 111, 112, 113, 114, 115, 116, 117, 118, 119, 120, 121, 122, 123, 124, 125, 126, 127, 128, 129, 130None None
ValuesstringUnknown, Other, Adapter/Card Error, Application Subsystem Failure, Bandwidth Reduced, Connection Establishment Error, Communications Protocol Error, Communications Subsystem Failure, Configuration/Customization Error, Congestion, Corrupt Data, CPU Cycles Limit Exceeded, Dataset/Modem Error, Degraded Signal, DTE-DCE Interface Error, Enclosure Door Open, Equipment Malfunction, Excessive Vibration, File Format Error, Fire Detected, Flood Detected, Framing Error, HVAC Problem, Humidity Unacceptable, I/O Device Error, Input Device Error, LAN Error, Non-Toxic Leak Detected, Local Node Transmission Error, Loss of Frame, Loss of Signal, Material Supply Exhausted, Multiplexer Problem, Out of Memory, Output Device Error, Performance Degraded, Power Problem, Pressure Unacceptable, Processor Problem (Internal Machine Error), Pump Failure, Queue Size Exceeded, Receive Failure, Receiver Failure, Remote Node Transmission Error, Resource at or Nearing Capacity, Response Time Excessive, Retransmission Rate Excessive, Software Error, Software Program Abnormally Terminated, Software Program Error (Incorrect Results), Storage Capacity Problem, Temperature Unacceptable, Threshold Crossed, Timing Problem, Toxic Leak Detected, Transmit Failure, Transmitter Failure, Underlying Resource Unavailable, Version MisMatch, Previous Alert Cleared, Login Attempts Failed, Software Virus Detected, Hardware Security Breached, Denial of Service Detected, Security Credential MisMatch, Unauthorized Access, Alarm Received, Loss of Pointer, Payload Mismatch, Transmission Error, Excessive Error Rate, Trace Problem, Element Unavailable, Element Missing, Loss of Multi Frame, Broadcast Channel Failure, Invalid Message Received, Routing Failure, Backplane Failure, Identifier Duplication, Protection Path Failure, Sync Loss or Mismatch, Terminal Problem, Real Time Clock Failure, Antenna Failure, Battery Charging Failure, Disk Failure, Frequency Hopping Failure, Loss of Redundancy, Power Supply Failure, Signal Quality Problem, Battery Discharging, Battery Failure, Commercial Power Problem, Fan Failure, Engine Failure, Sensor Failure, Fuse Failure, Generator Failure, Low Battery, Low Fuel, Low Water, Explosive Gas, High Winds, Ice Buildup, Smoke, Memory Mismatch, Out of CPU Cycles, Software Environment Problem, Software Download Failure, Element Reinitialized, Timeout, Logging Problems, Leak Detected, Protection Mechanism Failure, Protecting Resource Failure, Database Inconsistency, Authentication Failure, Breach of Confidentiality, Cable Tamper, Delayed Information, Duplicate Information, Information Missing, Information Modification, Information Out of Sequence, Key Expired, Non-Repudiation Failure, Out of Hours Activity, Out of Service, Procedural Error, Unexpected InformationNone TRANSLATABLE= true
ProbableCauseDescriptionstring
DescriptionstringProvides additional information related to the ProbableCause.None TRANSLATABLE= true
ModelCorrespondencestringCIM_AlertIndication.ProbableCauseNone None
ProviderNamestring
DescriptionstringThe name of the Provider generating this Indication.None TRANSLATABLE= true
MaxLenuint32256None None
RecommendedActionsstring
DescriptionstringFree form descriptions of the recommended actions to take to resolve the cause of the notification.None TRANSLATABLE= true
MappingStringsstringRecommendation.ITU|X733.Proposed repair actionsNone None
SystemCreationClassNamestring
DescriptionstringThe scoping System's CreationClassName for the Provider generating this Indication.None TRANSLATABLE= true
MaxLenuint32256None None
SystemNamestring
DescriptionstringThe scoping System's Name for the Provider generating this Indication.None TRANSLATABLE= true
MaxLenuint32256None None
DescriptionstringProvides information on trending - trending up, down or no change.None TRANSLATABLE= true
MappingStringsstringRecommendation.ITU|X733.TrendIndicationNone None
ValueMapstring0, 1, 2, 3, 4None None
ValuesstringUnknown, Not Applicable, Trending Up, Trending Down, No ChangeNone TRANSLATABLE= true

Copyright © 2008-2010 VMware, Inc. All rights reserved.