Class CIM_ClassModification


  extends CIM_ClassIndication
CIM_ClassModification notifies when a class definition in the schema is modified.
Details...
This class is not implemented.

Class Qualifiers

NameData TypeValueScopeFlavors
DescriptionstringCIM_ClassModification notifies when a class definition in the schema is modified.None TRANSLATABLE= true
IndicationbooleantrueNone OVERRIDABLE= false
UMLPackagePathstringCIM::EventNone None
Versionstring2.6.0TOSUBCLASS= falseTRANSLATABLE= true

Local Class Properties

NameData TypeQualifiers
NameData TypeValueScopeFlavors
ClassDefinitionstring
DescriptionstringThe current definition of the class that is created, changed or deleted in the schema. In the case of a CIM_ClassDeletion Indication, the definition for the class just prior to deletion should be placed in this property.None TRANSLATABLE= true
EmbeddedObjectbooleantrueNone OVERRIDABLE= false
RequiredbooleantrueNone OVERRIDABLE= false
CorrelatedIndicationsstring
DescriptionstringA list of IndicationIdentifiers whose notifications are correlated with (related to) this one.None TRANSLATABLE= true
MappingStringsstringRecommendation.ITU|X733.Correlated notificationsNone None
ModelCorrespondencestringCIM_Indication.IndicationIdentifierNone None
IndicationFilterNamestring
DescriptionstringAn identifier for the indication filter that selects this indication and causes it to be sent. This property is to be filled out by the indication sending service. The value shall be correlatable with the Name property of the instance of CIM_IndicationFilter describing the criteria of the indication. The value of the IndicationFilterName should be formatted using the following algorithm: < OrgID > : < LocalID >, where < OrgID > and < LocalID > are separated by a colon (:) and < OrgID > shall include a copyrighted, trademarked, or otherwise unique name that is owned by the business entity that is creating or defining the value or that is a registered ID assigned to the business entity by a recognized global authority. In addition, to ensure uniqueness, < OrgID > shall not contain a colon (:).When using this algorithm, the first colon to appear in the value shall appear between < OrgID > and < LocalID >. < LocalID > is chosen by the business entity and shall be used uniquely.None TRANSLATABLE= true
ExperimentalbooleantrueTOSUBCLASS= falseNone
ModelCorrespondencestringCIM_IndicationFilter.NameNone None
IndicationIdentifierstring
DescriptionstringAn identifier for the Indication. This property is similar to a key value in that it can be used for identification, when correlating Indications (see the CorrelatedIndications array). Its value SHOULD be unique as long as correlations are reported, but MAY be reused or left NULL if no future Indications will reference it in their CorrelatedIndications array.To ensure uniqueness, the value of IndicationIdentifier should be constructed using the following "preferred" algorithm: <OrgID>:<LocalID> Where <OrgID> and <LocalID> are separated by a colon (:), and where <OrgID> must include a copyrighted, trademarked, or otherwise unique name that is owned by the business entity that is creating or defining the IndicationIdentifier or that is a recognized ID that is assigned to the business entity by a recognized global authority. (This requirement is similar to the <Schema Name>_<Class Name> structure of Schema class names.) In addition, to ensure uniqueness <OrgID> must not contain a colon (:). When using this algorithm, the first colon to appear in IndicationIdentifier must appear between <OrgID> and <LocalID>. <LocalID> is chosen by the business entity and should not be re-used to identify different underlying (real-world) elements. If the above "preferred" algorithm is not used, the defining entity should assure that the resulting IndicationIdentifier is not re-used across any IndicationIdentifiers that are produced by this or other providers for the NameSpace of this instance. For DMTF-defined instances, the "preferred" algorithm should be used with the <OrgID> set to CIM.None TRANSLATABLE= true
MappingStringsstringRecommendation.ITU|X733.Notification identifierNone None
IndicationTimedatetime
DescriptionstringThe time and date of creation of the Indication. The property may be set to NULL if the entity creating the Indication is not capable of determining this information. Note that IndicationTime may be the same for two Indications that are generated in rapid succession.None TRANSLATABLE= true
OtherSeveritystring
DescriptionstringHolds the value of the user defined severity value when 'PerceivedSeverity' is 1 ("Other").None TRANSLATABLE= true
ModelCorrespondencestringCIM_AlertIndication.PerceivedSeverityNone None
PerceivedSeverityuint16
DescriptionstringAn enumerated value that describes the severity of the Indication from the notifier's point of view: 1 - Other, by CIM convention, is used to indicate that the Severity's value can be found in the OtherSeverity property. 3 - Degraded/Warning should be used when its appropriate to let the user decide if action is needed. 4 - Minor should be used to indicate action is needed, but the situation is not serious at this time. 5 - Major should be used to indicate action is needed NOW. 6 - Critical should be used to indicate action is needed NOW and the scope is broad (perhaps an imminent outage to a critical resource will result). 7 - Fatal/NonRecoverable should be used to indicate an error occurred, but it's too late to take remedial action. 2 and 0 - Information and Unknown (respectively) follow common usage. Literally, the Indication is purely informational or its severity is simply unknown.None TRANSLATABLE= true
MappingStringsstringRecommendation.ITU|X733.Perceived severityNone None
ValueMapstring0, 1, 2, 3, 4, 5, 6, 7None None
ValuesstringUnknown, Other, Information, Degraded/Warning, Minor, Major, Critical, Fatal/NonRecoverableNone TRANSLATABLE= true
PreviousClassDefinitionstring
DescriptionstringA copy of the 'previous' class definition whose change generated the Indication. PreviousClassDefinition contains an 'older' copy of the class' information, as compared to what is found in the ClassDefinition property (inherited from ClassIndication).None TRANSLATABLE= true
EmbeddedObjectbooleantrueNone OVERRIDABLE= false
RequiredbooleantrueNone OVERRIDABLE= false

Copyright © 2008-2010 VMware, Inc. All rights reserved.